Buzzing problems with dimmers

Buzzing problems with dimmers
Each good dimmer has a filter choke inside. Those chokes help to filter out electrical noise that often causes hum to be picked up in sound system and musical instrument pick-ups. The slower the current rise is, the less noise is picked by sound system.
The chokes also help to eliminate 'lamp singing' that can cause audible noise to come from the lighting fixtures. Lamps with power rating of 300W or more tend to more or less acoustic noise when dimmed. If this acoustic noise is a problem can be removed by adding a series coil which limits the current rise time to around 1 millisecond.
In providing those filtering functions, the chokes themselves can generate a slight buzz. Fast current changes in the coil can make the coil wiring and core material easily vibrate which causes buzzing noise. A little bit of buzzing is normal with filtered dimmers. If the buzz from dimmer can be a problem it is recommended that the dimmer is placed in the area where this buzz will not be a problem.
As far as the 'bulb singing' concerned, a bulb consists of a series of supports and, essentially, fine coils of wire. When the amount of current flow abruptly changes the magnetism change can be much stronger than it is on a simple sine wave. Hence, the filaments of the bulb will tend to vibrate more with a dimmer chopping up the wave form, and when the filaments vibrate against their support posts, you will get a buzz. If you have buzzing, it's always worth trying to replace the bulb with a different brand. Some cheap bulb brands have inadequate filament support, and simply changing to a different brand may help.
Buzzing bulbs are usually a sign of a "cheap" dimmer. Dimmers are supposed to have filters in them. The filter's job is to "round off" the sharp corners in the chopped waveform, thereby reducing EMI, and the abrupt current jumps that can cause buzzing. In cheap dimmers, they've economized on the manufacturing costs by cost-reducing the filtering, making it less effective.
In very high power dimming systems the wiring going to lighting can also cause buzzing. The fast current makes the electrical wiring to vibrate a little bit and if the wire is installed so that the vibration can be transferred to some other material then the buzzing could be heard. The buzzing caused by the vibration of the wiring is only problem in very high power systems like theatrical lighting with few kW of lights connected to the same cable. Better filtered dimmers can reduce the problem because the filter makes the current changes slower so the wires make less noise.